Skip to product information
1 of 10

JK

JK BMS 1A 2A Active Balance Lifepo4 BMS 8S 16S 24S 100A 150A 200A 500A Smart Board with Bluetooth

JK BMS 1A 2A Active Balance Lifepo4 BMS 8S 16S 24S 100A 150A 200A 500A Smart Board with Bluetooth

Regular price $69.99 USD
Regular price Sale price $69.99 USD
Sale Sold out
Taxes included.
Version
材料
Model Number
JK bms
Place of Origin
China
Apply to
Lifepo4/LTO/Li-ion
Brand Name
JK
Base Material
aluminum
Copper Thickness
1mm
Board Thickness
17.8mm-20.4mm
Min. Hole Size
<1mm
Min. Line Width
<1mm
Min. Line Spacing
<3mm
Surface Finishing
Three-layer anti-coating
Board Size
135*83*17.6mm/162*102*20mm
Product name
Jk Bms
Communication
RS485/CANbus/UART/Bluetooth(not for inverter)
MOQ
1pc
Discharge current
60A 80A 100A 150A 200A
Apply to
Lifepo4/LTO/Li ion Battery Pack
Voltage
24v-96v
With App
YES
Cerficate
CE
Material
aluminum
Customize
YES

 

View full details

Why Choose JK BMS

1.Active balance functionality, no need to lose the battery capacity to balance the voltage difference of cells, raise the battery usage efficiency for 95%
2.It has the protections of Over-charge/Over-discharge/Over-current and Short circuit Over-temperature protection etc...
3.Single battery series voltage range is 1~5V, the precision is 5mV
4.With the function of coulomb meter, the remaining power is very clear
5.BT communication function, the battery status can be displayed on APP

FAQ

The App is Chinese,I need English version

the language can be changed in the setting.

The BMS does not turn on,no light

1、Ensure that the last "B+" line of the cable has been connected to the total positive terminal of the battery.
2, charging activation boot, ensure that the charger voltage is greater than the battery pack voltage of 4V or more
before activation.
3, check whether the charger has voltage output.

The voltage is not correct

1、Measure the actual total voltage of the battery with a multimeter, and fill in the actual total voltage into the parameter setting page "Voltage Calibration".(voltage calibration" is on the setting page.)

The current is not correct

1, the B- and P- are two 7AWG wires, both need to be connected in parallel
Otherwise, it will lead to current errors.
2、Measure the actual current of the battery pack with a clamp meter, and fill in the actual current into the parameter setting page "current calibration".
egg page "current calibration" inside; the larger the actual current, the higher the calibration accuracy.

The capacity is not correct

1. An initial capacity is estimated according to the cell voltage when the BMS is powered on for the first time,and this capacity is not accurate;
2. But after the battery is discharged to 2.5V and then fully charged to 3.65V, it is calibrated.
This top-balance process cannot be interrupted;

The series number is not correct

Check the "Number of Units" in the settings
1. Whether the number is correct;
2.If there is no voltage in the middle of a series of 2 or more, check whether the collection line is disconnected